Stationary solutions and oscillatory dynamics in a mathematical model of a saturated moist atmosphere

Dalila Remaoun Bourega
Abstract

This paper investigates the mathematical properties of an idealized atmospheric system describing vertical air flows coupled with water-vapor condensation, conceptualized within the framework of bulk mass-flux convective models. We focus on two core aspects: establishing the rigorous existence of a long-term stationary equilibrium governed by an autonomous vector field over physically admissible regimes, and examining the transient oscillatory dynamics of the associated evolutionary system. Our numerical simulations display damped oscillations in the flow intensity α(t) and suspended condensate density Σ(t), consistent with a proposed delayed feedback mechanism driven by latent-heat release and droplet loading, where the irreversible fallout of condensate acts as a dissipative sink. The close numerical agreement between the asymptotic evolutionary states and the independently evaluated stationary profiles provides an internal verification of the analytical formulation. These findings offer a mathematically grounded perspective on vertical thermodynamic feedbacks, deliberately isolating core column balances from environmental entrainment and complex convective boundary-layer stability.

Share
1 Introduction

Atmospheric phenomena such as cumulonimbus clouds, tropical cyclones (Montgomery and Smith, 2017), and severe storms (Cotton et al., 2011) are driven by deep moist convection, in which upward air motion and water-vapor condensation are mutually sustaining thermodynamic processes. Accurately formulating this nonlinear coupling remains a fundamental task in geophysical fluid dynamics. In earlier studies (Aouaouda et al., 2019; Bourega et al., 2018; Ghomrani et al., 2015; Yashima, 2019), systems of differential equations were formulated to describe these regimes in terms of temperature (T), density (ρ), vertical velocity (v), and the vertically averaged suspended condensate density (Σ).

A recognized geometric constraint of early formulations assuming a uniform cylindrical geometry was an artificial acceleration of the vertical velocity with altitude (Ghomrani et al., 2015). To remedy this unphysical behavior, Bourega et al. (2018) introduced an axisymmetric vertical tube with variable cross-section S(z), engineered so that the parcel widens with height; under this geometry, the normalized vertical velocity remains essentially uniform in altitude while time-dependent modulations are accommodated.

Numerical integrations of this evolutionary model revealed marked oscillations in the vertical flow velocity and condensed water loading (Bourega et al., 2018). While convective rain rate variability is frequently investigated in connection with atmospheric gravity waves (Plougonven and Zhang, 2014; Richiardone and Manfrin, 2003), our model suggests a complementary, column-internal candidate mechanism: upward motion triggers condensation and latent-heat release, which warms the air and accelerates ascent; the subsequent accumulation of condensate adds mechanical drag through parcel loading, which decelerates the updraft and suppresses droplet production, allowing fallout to clear the column and reinitiate the ascent. We present this mechanism as a proposed delayed feedback model rather than an exhaustive causal explanation, noting that it isolates vertical thermodynamics in the absence of high-resolution large-eddy simulation (LES) or radar validation.

In broader meteorological contexts, this simplified setup shares conceptual roots with bulk mass-flux convective parameterization schemes (Arakawa and Schubert, 1974; Emanuel, 1991; Plant, 2010; Zhang and McFarlane, 1995). Realistic mass-flux frameworks incorporate continuous environmental entrainment and detrainment, producing buoyancy dilution along ascending plumes. In our formulation, lateral mixing is neglected, and the variation of the cross-sectional area S(z) is purely a geometric consequence of mass conservation under a uniform normalized velocity profile. This abstraction isolates the vertical thermodynamic feedback while keeping the analytical system tractable.

The primary objective of this study is to establish the rigorous existence of the stationary solution for this system over physically admissible regimes. The stationary state defines the long-term equilibrium around which oscillations occur. We reformulate the spatial structure as a two-dimensional vector field (T′,ρ′), bypassing earlier strict monotonicity and uniqueness arguments, to prove solvability via continuity and quantitative domain bounds. Furthermore, we provide a robust numerical verification addressing previously observed boundary discrepancies, and briefly contextualize the damped relaxation as a generic property of memory-delayed restoring forces.

2 The full evolutionary model

Following Bourega et al. (2018), we describe the upward flow of moist air within an axisymmetric vertical tube Ω3={(x,y,z)∈R3∣0≤z≤z‾1,(x2+y2)π≤S(z)} using the velocity decomposition v(t,z)=α(t)w(t,z), where w represents the normalized vertical velocity and α(t) governs flow intensity. Under a quasi-stationary spatial approximation (∂tw≈0, ∂tρ≈0, ∂tT≈0), pressure satisfies the ideal gas equation of state P = R1ρT, where R1=R0/μa (μa=28.96gmol-1 for dry air).

The density of saturated water vapor, π‾vs(T), is defined according to Matveev (1984) by

(1) π ‾ vs ( T ) = E 0 R v T × 10 7.63 ( T - 273.15 ) T - 31.25 , E 0 = 6.107 mbar = 610.7 Pa , R v = R 0 / μ v ,

where μv=18.02gmol-1 is the molar mass of water vapor, giving Rv≈461.5Jkg-1K-1. Using Rv correctly converts saturation vapor pressure into density (π‾vs(293K)≈17.2gm-3), avoiding the significant overestimation that would result from using R1. The expression is restricted to temperatures above the singular boundary Θ-=31.25K.

Assuming the ascending parcel remains continuously saturated without lateral entrainment, the phase-change rate per unit volume Htr along the vertical trajectory is given by

(2) H tr = π ‾ vs ( T ) d d z log ρ - d d z π ‾ vs ( T ) v .

The associated latent heat release is LtrHtr, where Ltr denotes the latent heat of condensation. Neglecting molecular diffusion, the system obeys the conservation laws:

(3)S(z)∂ρ∂t+∂∂z(S(z)ρv)=-S(z)Htr,(4)ρ∂v∂t+v∂v∂z=-R1∂∂z(ρT)-g[Σ+ρ],(5)ρcv∂T∂t+v∂T∂z-R1T∂ρ∂t+v∂ρ∂z=(R1T+Ltr)Htr,

where g is the gravitational acceleration and cv=52R1 is the isochoric specific heat capacity. The height-averaged suspended condensate density Σ(t) satisfies the memory integral

(6) Σ ( t ) = 1 z ‾ 1 ∫ 0 t φ ( t - s ) α ( s ) ∫ 0 z ‾ 1 π ‾ vs ( T ) ∂ ∂ z log ρ - ∂ ∂ z π ‾ vs ( T ) w d z d s ,

with the Gaussian kernel

(7) φ ( τ ) = exp - π τ 2 4 b 2 , b = ∫ 0 ∞ φ ( τ ) d τ .

The scale parameter b represents the mean droplet residence time before precipitation fallout. We set b=450 s (7.5 min) as a representative timescale ensuring resolved numerical relaxation.

3 The stationary formulation

In the stationary limit, time derivatives vanish and the unknowns satisfy α(t)≡α, Σ(t)≡Σ. To maintain a normalized profile w≡1, the cross-sectional area S(z) is determined inversely from mass conservation, Eq. (3):

(8) S ( z ) = ρ 0 S ( 0 ) ρ ( z ) exp π ‾ vs ( T ( z ) ) ρ ( z ) - π ‾ vs ( T 0 ) ρ 0 .

The stationary boundary-value problem on 0<z<z‾1 reduces to:

(9)ρcvdTdz-R1Tdρdz=R1T+Ltrπ‾vs(T)1ρdρdz-dπ‾vs(T)dTdTdz,(10)R1ρdTdz+R1Tdρdz=-g[Σ+ρ],(11)Σ=αbz‾1∫0z‾1π‾vs(T)ddzlogρ-ddzπ‾vs(T)dz,

subject to the initial and top boundary data:

(12) ρ ( 0 ) = ρ 0 , T ( 0 ) = T 0 , ρ ( z ‾ 1 ) T ( z ‾ 1 ) = q 0 .

Here q0=P(z‾1)/R1 denotes the boundary pressure proxy, fixed by a reference hydrostatic profile.

4 Existence of the stationary solution

Reference target profiles (ρhs[ϑ],Ths[ϑ]) are constructed via the homotopy system:

(13)ρcvdTdz-R1Tdρdz=ϑR1T+Ltrπ‾vs(T)ddzlogρ-ddzπ‾vs(T),(14)R1ddz(ρT)=-gρ,ρ(0)=ρ0,T(0)=T0,

where ϑ∈[0,1] parameterizes the condensation intensity (ϑ = 0 for dry, ϑ = 1 for fully saturated).

Resolving Eq. (9) and the auxiliary momentum equation ddz(R1ρT)=-gρ-c0 yields the explicit planar vector field:

(15) d T d z d ρ d z = D 1 ( ρ , T , c 0 ) D 2 ( ρ , T , c 0 ) ,

where c0=gΣ≥0 is the constant shooting parameter. Our aim is to apply the shooting method to find the specific value of c0 that satisfies the top boundary pressure condition. The explicit components of the planar vector field are given by:

(16)D1(ρ,T,c0)=-R1T+LtrR1ρTπ‾vs(T)+1(gρ+c0)Den(ρ,T),(17)D2(ρ,T,c0)=-ρcv+(R1T+Ltr)dπ‾vs(T)dT(gρ+c0)R1TDen(ρ,T),

where the algebraic denominator is defined as:

(18) Den ( ρ , T ) = ρ ( c v + R 1 ) + ( R 1 T + L tr ) π ‾ vs ( T ) T + d π ‾ vs ( T ) d T .

This algebraic denominator is strictly positive for all T>Θ-=31.25K and ρ>0. The threshold Θ+≈1276.0K marks the theoretical upper bound for saturation consistency.

Before stating the existence theorem, we define the critical altitude z‾* associated with the dry reference profile:

(19) z ‾ * = c v + R 1 g ( T 0 - 31.25 ) ,

and we introduce the analytical temperature threshold Θ1≈66.10 K, uniquely defined by the root of the following thermodynamic relation:

(20) c v + R 1 R 1 π ‾ vs ( T ) - π ‾ vs ( T ) T - d π ‾ vs ( T ) d T = 0 at  T = Θ 1 ,

which ensures that the expression is strictly positive for T>Θ1.

Proposition 1 (Conditional Existence of Stationary Solutions). Let ρ0>0 and T0∈]Θ1,Θ+[, with z‾1∈]0,z‾*[ such that Ths[1](z‾1)>Θ1. For any compact subset of the physical domain D={ρ>0,T>Θ-} and any maximum shooting parameter c0max such that all trajectories (ρc0,Tc0) remain strictly within this compact subset for all z∈[0,z‾1] and all c0∈[0,c0max], the following holds: for each prescribed target q0 attained by the endpoint map ν(c0)=ρc0(z‾1)Tc0(z‾1) over this range – in particular the dry and humid targets studied numerically in Sect. 5 – the problem given by Eqs. (9)–(12) admits a stationary solution (ρ,T,α).

We are not able to check analytically that the trajectories remain bounded away from the singular boundaries for all possible values of c0; however, we provide robust numerical evidence of this confinement for the entire operational shooting range in Appendix B.

The vector field of Eq. (15) is locally Lipschitz on D, so Picard–Lindelöf gives a unique local solution for every c0≥0; the gap between this local statement and existence on the full interval [0,z‾1] is closed by the escape-alternative argument and the quantitative numerical verification detailed in Appendix B. Once an admissible c0 is identified, the flow coefficient α is explicitly determined by Eq. (11). We refrain from asserting uniqueness, as sign changes in cross-derivatives preclude global strict monotonicity.

5 Numerical examples

5.1 Stationary solution

We use g=9.8ms-2, R0=8.314Jmol-1K-1, μa=28.96gmol-1 (so R1=R0/μa, cv=52R1, consistent with a diatomic gas), μv=18.02gmol-1 (so Rv=R0/μv≈461.5Jkg-1K-1, used in Eq. 1), and the temperature-dependent latent heat Ltr(T)=(3244-2.72T)×103 J kg−1 for the numerical results, while the analytic proofs treat Ltr as constant for simplicity – a simplification that does not affect the non-singular nature of the vector field underlying the existence theorem (Appendix B), since the prefactor g(R1T+Ltr) remains strictly positive whether Ltr is constant or a function of T within the physical range.

With z‾1=10000m, ρ0=1.2055kgm-3, T0 = 293 K, we compute two reference cases for the boundary target q0: dry (ϑ = 0, q0≈85.52kgKm-3) and humid (ϑ=2/3, q0≈94.09kgKm-3), yielding Σ=0.0562kgm-3 (dry) and Σ=0.0153kgm-3 (humid). Table 1 reports the exact numerical endpoint values extracted from the simulation, demonstrating the successful matching of the boundary product ρ(z‾1)T(z‾1) with the theoretical target q0.

Table 1Numerical endpoint values at z=z‾1 for the stationary profiles at different spatial resolutions (Δz = 10, 5, and 1 m), confirming the grid convergence and the matching of the target boundary conditions.

Download Print Version | Download XLSX

As demonstrated in Table 1, the endpoint values of density and temperature are remarkably stable across spatial resolutions, varying by less than 0.05 K between Δz=10 m and Δz=1 m. While these primary spatial profiles are already robust at coarser resolutions, refining the grid is necessary to stabilize the cumulative integral required for α. The slight baseline adjustments in the target q0 simply reflect the increased numerical precision of the underlying hydrostatic reference calculation.

Note that the time-dependent evolutionary simulation in Sect. 5 employs Δz = 10 m. The time-marching integration is inherently less sensitive to this spatial step than the stationary boundary-value solver, as it relies on a dissipative upwind scheme rather than the highly sensitive numerical evaluation of a boundary pressure mismatch, ensuring stable convergence toward the asymptotic state.

Figure 1 shows the resulting ρ(z), T(z) profiles; the temperature profile for the humid case departs markedly from the dry case because of latent-heat release, validating the underlying thermodynamics, while the density profiles remain close, since the atmosphere stays close to hydrostatic equilibrium in both cases. Figure 2 shows the continuous target map ν(Σ) underlying the existence proof of Proposition 1, evaluated across the admissible parameter space.

https://npg.copernicus.org/articles/33/569/2026/npg-33-569-2026-f01

Figure 1Distribution of density and temperature for the stationary solution (dry case, ϑ = 0, and humid case, ϑ=2/3).

Download

https://npg.copernicus.org/articles/33/569/2026/npg-33-569-2026-f02

Figure 2Dependence of ρ(z‾1)T(z‾1) on Σ, illustrating the continuity and topological structure of the endpoint map ν used in the proof of Proposition 1.

Download

5.2 Evolutionary model: damped oscillations

Using b = 450 s, ϑ=2/3, and the discretization ht = 10 s, hz = 10 m, Fig. 3 shows α(t) and Σ(t) over 7400 s, starting from the same ρ0, T0, z‾1 as above. The two curves are strongly correlated, consistent with the cyclical mechanism described in Sect. 1, and both converge toward the values predicted independently by the stationary solution: Σstat≈0.0153 kg m−3 and αstat≈32.87 (see stationary results, humid case), which we regard as an internal consistency check between the two halves of this study rather than an external validation against observations.

https://npg.copernicus.org/articles/33/569/2026/npg-33-569-2026-f03

Figure 3Damped oscillations of α(t) and Σ(t) converging to the stationary target.

Download

5.2.1 Physical interpretation of the amplitude decay

As described in the Introduction, the ascent of moist air produces condensation, releasing latent heat that warms the air and accelerates its ascent; the accumulation of the resulting droplets then slows the vertical flow through their weight, which reduces droplet production and, combined with the gradual fallout of existing droplets, allows the ascending flow to resume. This mechanism is not conservative: the fallout of droplets out of the convective column is an irreversible loss of condensed mass, statistically encoded in the memory kernel φ. This loss acts as a dissipative term, analogous to friction in a classical damped oscillator: at each cycle, part of the mechanical energy available to sustain the acceleration/deceleration contrast is removed from the system together with the falling water. The amplitude of the oscillations of α(t) and Σ(t) therefore decreases progressively, until the system reaches the stationary state, where condensate production by the ascending flow exactly balances its loss by fallout.

https://npg.copernicus.org/articles/33/569/2026/npg-33-569-2026-f04

Figure 4Convergence of the evolutionary simulation toward the stationary state. (a) Density profile ρ(z) at final time, converging toward the humid stationary profile. (b) Evolution of the normalized velocity w(t) at mid-height, showing convergence of the spatial structure. Additional profiles – temperature, final-time w(z), and the section profile S(z) – can be reproduced with the Python scripts available on Zenodo (Bourega, 2026).

Download

Exploratory runs at other values of b, using the same numerical scheme, confirm this picture and reveal an important boundary of the model's validity. At b≈150 s (about one third of the base value), α(t) rises rapidly and settles onto a plateau with no visible oscillation within the tested window, consistent with short memory producing a nearly monotone approach to equilibrium, as expected when the restoring feedback acts with little delay. At b≈900 s (twice the base value), by contrast, the oscillation amplitude grows much larger than at b=450 s, and α(t) transiently becomes negative, reaching values below −25 within the tested window; this was verified at both a coarser spatial resolution and at the paper's reference resolution hz = 10 m, with closely matching trajectories, ruling out a discretization artifact. We do not interpret this negative-α behavior as a physical prediction of the model: the derivation of the condensation rate Htr in Sect. 2 explicitly assumes an ascending, saturated parcel with v=αw>0, so once α(t)<0 the numerical solution, although still well-defined mathematically (the underlying linear systems remain non-singular), is being extrapolated outside the regime for which the underlying physics was derived – descending, adiabatically warming air is not expected to condense water vapor by the same mechanism. This indicates a practical upper bound on b beyond which the present formulation is no longer physically applicable within a simulation window of this length, rather than evidence that the oscillatory regime itself becomes unstable. By contrast, at b = 450 s, α(t) remains strictly positive throughout the simulation (its minimum value stays close to but above zero), so the detailed comparison of Fig. 3 with the stationary prediction is carried out entirely within the model's region of physical validity. This validity constraint does not affect the existence result of Sect. 4: the stationary construction of Proposition 1 is built from c0≥0, which by Eq. (11) yields αstat≥0 by construction, so the stationary branch of the model always corresponds to a physically ascending column, independently of b. Determining the true (rather than practical) upper bound on b for which the evolutionary model remains applicable – and extending the formulation to properly describe the descending/downdraft regime – is left for future work, together with the observational calibration discussed below. The value b = 450 s retained for the detailed comparison of Fig. 3 is not only the value for which convergence to the stationary state is most clearly resolved within a computationally tractable window, but also the one for which the simulation stays within the model's physical region of validity throughout – it was not selected post hoc to force agreement, since Eq. (11) shows Σstat is independent of b while αstat scales as 1/b, so the stationary target itself moves with b and is recomputed independently for each case. As noted in Sect. 2, b = 450 s itself sits below the range of warm-rain coalescence timescales reported from observations (of order 26 min to a few hours, Stephens and Haynes, 2007) and from classical parcel-model simulations (of order 60 min, Jonas, 1996); calibrating b against this broader observational range – which our exploratory runs suggest would already approach the boundary of the model's present region of validity – together with a full sensitivity sweep, is an important next step that we leave for future work.

Figure 4 completes the picture with the final-time spatial profiles of the evolutionary simulation, confirming convergence toward the humid stationary state of Fig. 1.

5.2.2 A qualitative Volterra analogy

The damped oscillations above are qualitatively analogous to those of a Volterra integro-differential equation y′(t)=-a∫0tK(t-s)(y(s)-c)ds+d with the same Gaussian memory kernel K(τ)=exp(-πτ2/4b2) (Volterra, 1931; Gopalsamy, 1987): simulating this scalar equation with b = 450 s produces a solution y(t), and an associated positive functional Ψ(t)=a∫0tK(t-s)y(s)ds, that display the same qualitative damped, correlated oscillatory convergence as α(t) and Σ(t) (with y playing the role of α and Ψ the role of Σ). We do not present this as a rigorous reduction of the full storm PDE system to a scalar ODE – the two problems differ in structure, and the analogy should be read purely as an illustration that delayed, memory-based restoring feedback of this Gaussian-kernel type generically produces damped oscillatory relaxation toward equilibrium, reinforcing the interpretation of b as the parameter controlling this relaxation.

6 Conclusion

The full evolutionary system, previously studied in (Bourega et al., 2018), describes idealized deep moist convection driven by ascending air flow and condensation. This article's main contribution is a rigorous existence result for the stationary solution of the associated simplified system given by Eqs. (9)–(12), established over the physically admissible shooting range verified in this study, by formulating the spatial structure as a non-singular autonomous vector field (Proposition 1, proved in Appendix B). Numerical examples, including a grid convergence study, illustrate this result and show that the converged evolutionary variables α(t), Σ(t) approach, as an internal consistency check, the values independently predicted by the stationary boundary-value theory. The damped nature of these oscillations is consistent with the irreversible loss of condensed water through droplet fallout, and shares a qualitative analogy with integro-differential equations governed by the same delay memory parameter b. Future work could extend this analytical framework to incorporate a self-consistent determination of the domain height z‾1 (e.g. via a level-of-neutral-buoyancy criterion), and connect the present idealized setup more closely to entraining-plume mass-flux parameterizations utilized in large-scale climate models.

Appendix A: Hydrostatic reference state

We recall the reference hydrostatic problem given by Eqs. (13)–(14) and denote by (ρhs[0],Ths[0]) its solution for ϑ = 0.

Lemma 1.

Assume ρ0>0 and Θ-<T0<Θ+. Then the problem given by Eqs. (13)–(14) admits a unique continuously differentiable solution (ρ,T) on [0,z‾∗[. Moreover ρ(z) and T(z) are strictly decreasing, and T(z)≥Ths[0](z) for all z∈[0,z‾∗[.

Proof. Dividing Eq. (13) by ρT transforms it into ddzlog(Tcv/ρR1)=-ϑ(R1+Ltr/T)ddz(π‾vs/ρ). Since Eq. (14) gives ddz(ρT)<0, ρ and T cannot both be non-decreasing at any point; a contradiction argument using Θ-<T<Θ+ then shows both are strictly decreasing and that ddz(π‾vs/ρ)≤0. Integrating the transformed equation and substituting into Eq. (14) yields an explicit, separable equation for T(z), whose solution is bounded below by Ths[0](z)=T0-gcv+R1z. These bounds ensure the local solution can be smoothly extended over the entire interval [0,z‾∗[.

Appendix B: Vector field formulation and global existence

We embed Eq. (10) into the auxiliary continuous family ddz(R1ρT)=-gρ-c0, with the constant shooting parameter c0≥0.

Lemma 2.
c0-independent monotonicity

Along any solution (ρ,T) of the vector field of Eq. (15), the quantity

(B1) Q ( z ) := c v ln T ( z ) - R 1 ln ρ ( z )

is non-decreasing in z, for every value of the shooting parameter c0≥0.

Proof. Equation (9), from which D1 and D2 are algebraically derived, does not involve c0: the parameter enters only through the auxiliary momentum equation. Dividing Eq. (9) by ρT gives, after rearrangement,

(B2) d Q d z = - R 1 + L tr T d d z π ‾ vs ( T ) ρ ,

which is exactly the identity used in the proof of Lemma 1 at ϑ=1, and is therefore valid independently of the value of c0. Since R1+Ltr/T>0 and ddz(π‾vs/ρ)≤0 (established in the proof of Lemma 1), we obtain dQ/dz≥0. □

Proof of Proposition 1. By algebraically solving the coupled system composed of Eq. (9) and the auxiliary momentum equation for the spatial derivatives dT/dz and dρ/dz, we obtain an explicit, autonomous planar vector field (D1,D2) as in Eq. (15). The algebraic denominator is strictly positive for all T>Θ- and ρ>0; hence the vector field is locally Lipschitz on the open physical domain D={(ρ,T):ρ>0,T>Θ-}.

By the Picard–Lindelöf theorem, for every c0≥0 there is a unique maximal solution (ρc0,Tc0) on [0,z∗(c0)) starting at (ρ0,T0). By the standard continuation (escape) alternative for ODEs, either z∗(c0)>z‾1 – so that the solution is defined on the full interval [0,z‾1] – or the trajectory leaves every compact subset of D as z→z∗(c0)-≤z‾1.

To establish the strict negativity of the vector field components D1 and D2 on the physical domain D, we perform a dedicated sign analysis. From the explicit definitions in Eqs. (16) and (17), the algebraic denominator Den(ρ,T) is strictly positive for T>Θ- and ρ>0. Since c0≥0, the numerator of D1 is trivially strictly positive, yielding dTdz=D1<0. By utilizing the established condition that T′≤0, we obtain an upper bound on T which, combined with the positivity of dπ‾vsdT and the physical constants in the numerator of D2, ensures that D2<0 as well. Consequently, both ρc0 and Tc0 are strictly decreasing functions along the trajectory, providing the strict upper bounds ρ(z)≤ρ0 and T(z)≤T0; in particular, the trajectory cannot diverge to infinity. Consequently, the only two mathematical mechanisms by which the trajectory could leave D before z‾1 are Tc0(z)→Θ-+ or ρc0(z)→0+ at some finite z≤z‾1. Because ρ is monotonically decreasing, its infimum over [0,z] is attained at z itself, so excluding ρ(z)→0 reduces to a direct numerical check of ρ(z‾1)>0; we verify this together with the analogous check for T below.

We rule out both escape mechanisms for the shooting range actually used to locate the reported solutions. The numerical procedure searches for the root of ν(c0)=ρc0(z‾1)Tc0(z‾1)=q0 over c0∈[10-7,0.170g]≈[0,1.666] (in SI units), which generously brackets both reported physical roots, c0=gΣdry≈0.551 and c0=gΣhumid≈0.150. Direct numerical integration of (D1,D2) over this entire bracket (Table B1) confirms that Tc0(z) remains strictly above 200 K throughout [0,z‾1] for every c0 tested – a margin exceeding 170 K above Θ-=31.25K – and that ρc0(z‾1) remains no smaller than 0.30, far from 0, across the same range. A dedicated computational bisection further shows that the trajectory only reaches Θ− at z=z‾1 for a critical shooting parameter c0crit≈4.70, about 2.8 times larger than the upper end of the bracket explored; at this critical point, ρ(z‾1)≈0.0028>0 remains strictly positive while T→Θ-+, confirming that temperature reaching the singular boundary – not density vanishing – is the operative escape mechanism in this model. This confirms that the trajectory remains in a fixed compact subset of D throughout [0,z‾1], excluding the escape alternative and establishing existence of (ρc0,Tc0) on the full interval [0,z‾1] for every c0 in this verified operational range.

Table B1Numerical verification that the trajectory (ρc0,Tc0) remains within a compact subset of D throughout z∈[0,z‾1], for c0 ranging from 0 to the maximum of the shooting bracket actually used (c0max=0.170g≈1.666), and up to the critical value c0crit at which the trajectory first reaches the singular boundary Θ-=31.25K. All quantities are computed by direct integration of the vector field of Eq. (15) with rtol=10-9, atol=10-11.

Download Print Version | Download XLSX

Since the endpoint map ν is well-defined and continuous on [0,1.666], and ν(c0dry)=q0dry, ν(c0humid)=q0humid are attained within this interval by construction, the existence of c0 solving ν(c0)=q0 follows directly. Once c0 is identified, the flow intensity α is reconstructed explicitly via Eq. (11), and Σ=c0/g. This establishes the existence of the stationary atmospheric state (ρ,T,α) for the configurations presented in this study.

Remark 1. The argument above establishes rigorous existence for the shooting range verified numerically. A fully analytic, closed-form a priori bound extending Lemma 1 unconditionally to the entire c0-family remains open. However, for the physical parameter ranges considered in atmospheric convection, the quantified safety margin (c0crit/c0max≈2.8) demonstrates that this theoretical limitation is not a binding physical restriction in practice.

□

The safety factor between the shooting bracket actually used and the rupture threshold is c0crit/c0max≈4.7028/1.666≈2.8. At the rupture point itself, ρ(z‾1)≈0.0028>0 remains strictly positive while T→Θ-+, confirming that the escape mechanism observed numerically is the temperature approaching the singular threshold, not the density vanishing.

Code availability

The complete Python scripts used for the numerical simulations and figures presented in Sect. 5 and Appendix B, together with documentation, are publicly available on Zenodo at https://doi.org/10.5281/zenodo.24321195 (Bourega, 2026).

Data availability

No external or experimental data sets were used in this theoretical study.

Competing interests

The contact author has declared that there are no competing interests.

Disclaimer

Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. The authors bear the ultimate responsibility for providing appropriate place names. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.

Acknowledgements

The author would like to express her gratitude to Hisao Fujita Yashima (National Higher School of Mathematics, NHSM-Sidi Abdellah, Algeria) for useful discussions and valuable insights, and to the Research Laboratory in Pure and Applied Mathematics (LRPAM), University of Science and Technology of Oran Mohamed-Boudiaf (USTO-MB), for institutional support. The author also thanks the anonymous referees for their thorough and constructive reviews that substantially improved the mathematical rigor and physical clarity of this manuscript.

Review statement

This paper was edited by Stéphane Vannitsem and reviewed by Boualem Khouider and one anonymous referee.

References

Aouaouda, M., Ayadi, A., and Yashima, F. H.: Mathematical modeling of tropical cyclones on the basis of wind trajectories, Comput. Math. Math. Phys., 59, 1493–1507, 2019. a

Arakawa, A. and Schubert, W. H.: Interaction of a cumulus cloud ensemble with the large-scale environment, Part I, J. Atmos. Sci., 31, 674–701, 1974. a

Bourega, D. R.: Python scripts for: Stationary solutions and oscillatory dynamics in a mathematical model of a saturated moist atmosphere, Zenodo [code], https://doi.org/10.5281/zenodo.24321195, 2026. a, b

Bourega, D. R., Aouaouda, M., and Fujita Yashima, H.: Rain oscillation in a mathematical model of a thunderstorm, Ann. Math. Afr., 7, 19–35, 2018. a, b, c, d, e

Cotton, W. R., Bryan, G. H., and Van den Heever, S. C.: Storm and Cloud Dynamics, 2nd Edn., Elsevier, Amsterdam, ISBN 978-0-12-088542-8, 2011. a

Emanuel, K. A.: A scheme for representing cumulus convection in large-scale models, J. Atmos. Sci., 48, 2313–2335, 1991. a

Ghomrani, S., Marín Antuña, J., and Fujita Yashima, H.: A model of air ascent caused by vapor condensation and its numerical calculation, Rev. Cubana Fís., 32, 3–8, 2015. a, b

Gopalsamy, S. K.: Oscillations in integrodifferential equations of arbitrary order, J. Math. Anal. Appl., 126, 100–109, 1987. a

Jonas, P. R.: Turbulence and cloud microphysics, Atmos. Res., 40, 283–306, 1996. a

Matveev, L. T.: Cloud Dynamics, Atmospheric and Oceanographic Sciences Library, vol. 2, D. Reidel, Dordrecht, https://doi.org/10.1007/978-94-009-6360-3, 1984. a

Montgomery, M. T. and Smith, R. K.: Recent developments in the fluid dynamics of tropical cyclones, Annu. Rev. Fluid Mech., 49, 541–574, 2017. a

Plant, R. S.: A review of the theoretical basis for bulk mass flux convective parameterization, Atmos. Chem. Phys., 10, 3529–3544, https://doi.org/10.5194/acp-10-3529-2010, 2010. a

Plougonven, R. and Zhang, F.: Internal gravity waves from atmospheric jets and fronts, Rev. Geophys., 52, 33–76, 2014. a

Richiardone, R. and Manfrin, M.: A rain episode related to a mesoscale gravity wave, B. Am. Meteorol. Soc., 84, 1494–1498, 2003. a

Stephens, G. L. and Haynes, J. M.: Near-global observations of the warm rain coalescence process, Geophys. Res. Lett., 34, L20805, https://doi.org/10.1029/2007GL030259, 2007.  a

Volterra, V.: Leçons sur la théorie mathématique de la lutte pour la vie, Gauthier-Villars, Paris, 1931. a

Yashima, F. H.: Modeling the internal structure of tropical cyclones: flow equation on wind trajectories, J. Math. Sci., 242, 747–759, 2019. a

Zhang, G. J. and McFarlane, N. A.: Sensitivity of climate simulations to the parameterization of cumulus convection in the Canadian Climate Centre general circulation model, Atmos.-Ocean, 33, 407–446, 1995. a

Download
Short summary
This study examines a simplified mathematical model of a rising column of moist air in which water vapour condenses into droplets. We show that a steady state of this column exists for realistic conditions, using a mathematical argument supported by careful numerical checks. Simulations show that the updraft and the amount of suspended water oscillate and slowly settle to this steady state, because released heat speeds up the rising air while the weight and fallout of droplets slow it down.